船用氣體樣氣預(yù)處理系統(tǒng)
博純的產(chǎn)品被廣泛應(yīng)用于工業(yè)領(lǐng)域中。八大應(yīng)用區(qū)域已被羅列至下表中,請點(diǎn)擊查看每個產(chǎn)品應(yīng)用領(lǐng)域::1、OEM 醫(yī)療設(shè)備- 呼吸氣體分析2、OEM 分析設(shè)備3、煙囪測試和排放物監(jiān)測4、環(huán)境空氣監(jiān)測5、 燃料電池應(yīng)用6、實(shí)驗室和科學(xué)研究7、CO2 保溫箱和環(huán)境加濕8、行業(yè)源樣氣預(yù)處理。
船用氣體樣氣預(yù)處理系統(tǒng)
博純用于制造醫(yī)療設(shè)備和呼吸氣體分析的產(chǎn)品
博純公司是通過ISO 13485 認(rèn)證的醫(yī)療設(shè)備制造商,供應(yīng)*的樣氣采樣管線、氣體干燥器和水分交換器,這些產(chǎn)品廣泛應(yīng)用在麻醉監(jiān)護(hù)、壓力測試/肺功能檢查、碳酸波形圖(二氧化碳監(jiān)控)和哮喘監(jiān)控(一氧化氮)上。我們的產(chǎn)品技術(shù)主要應(yīng)用在去除呼吸樣氣中的濕氣,以方便精確分析呼吸氣體。
船用柴油排放物SO2監(jiān)測
使用博純Nafion技術(shù)樣氣預(yù)處理系統(tǒng)測量SO2
博純提供Nafion技術(shù)樣氣預(yù)處理系統(tǒng)和Nafion干燥管確保SO2測量的準(zhǔn)確性。根據(jù)MEPC184(59)- 廢氣凈化系統(tǒng)的指導(dǎo)方針,為合規(guī)定SO2可以在濕式洗滌輸出時被測量,以防船舶操作者在ECAs(排放控制區(qū)域)不選擇含硫量為0.1%的燃燒燃料。因為SO2水平在洗滌后的含量極低,低水平的SO2將在溶解于冷凝水中,因此半導(dǎo)體冷凝器不能很好的處理樣氣。只有在使用博純Nafion氣體干燥管的氣體預(yù)處理系統(tǒng)才能在水氣階段消除樣氣中的水氣,*保樣氣中的SO2用于精準(zhǔn)分析。
博純?yōu)榇肧O2分析儀提供一下產(chǎn)品選項:
| 用于系統(tǒng)的船用樣氣干燥管部件 |
用于監(jiān)測SO2的Indi-GASS 樣氣預(yù)處理系統(tǒng)
IndiGASS 船用氣體預(yù)處理系統(tǒng) – 帶有堅固的Nema / Type 4x耐腐蝕外殼,非常適用于船舶環(huán)境。Indi-GASS™系統(tǒng)為高性能SO2氣體分析準(zhǔn)備熱樣氣流。Indi-GASS將顆粒物,酸霧和水氣從排放物氣流中移除,而不流失SO2。Nafion系統(tǒng)是*一種可以從樣氣中移除水氣而不會影響SO2成分的產(chǎn)品。在低硫水平,傳統(tǒng)冷凝器將流多達(dá)90%的分析物,因此不能用于精確測量。連接到博純Indi-GASS樣氣預(yù)處理系統(tǒng)獲取更多信息。
下載演示– 用于船用分析的IndiGASS
PD系列Nafion樣氣干燥管
The PD (多管) 系列 氣體干燥器把水分從一股氣流轉(zhuǎn)移至另一股反向吹掃的氣流,就像是一個管殼式的熱轉(zhuǎn)換器轉(zhuǎn)移熱量。水分子通過Nafion膜壁滲透,然后蒸發(fā)至吹掃氣體中。 這被用在Indi-GASS,同時也被樣氣預(yù)處理系統(tǒng)OEM廠商所選擇使用。各種長度和管徑可供用戶選擇,可應(yīng)用在1-40LPM樣氣流速中。他們因在世界嚴(yán)峻的CEMS應(yīng)用中高性能和*的可靠性而*。連接到PD系列。
Providing more accurate process control and environmental monitoring
Combustion and process gas samples are typically wet, dirty, and hot, while analysers need samples to be dry, clean, and cool. Designed specifically to meet the needs of the India market, the new GM-1024 Indi-GASS Sample Conditioning Module from Perma Pure produces an ideal dry, clean, and cool sample by continuously removing water and particulates from the sample stream, without altering the concentrations of typical analyte gases (including CO, CO2, HCl, NOX, O2, SO2, and VOC).
The Indi-GASS brings maximum performance in a compact module to systems integrators and OEM manufacturers of gas analysis systems. Inputs to the system are the gas sample, compressed air, and electrical power and the output is a dry, clean, and cool sample ready for analysis. Electronics and controls have been kept to a minimum to provide the necessary functionality at an affordable price point.
The device uses patented Nafion™ membrane technology to remove water in the vapour phase, allowing users to achieve far lower dew points while quantitatively preserving analyte levels. Drying is a continuous, self-regenerating process and no routine maintenance is required. By contrast, chiller/condensers remove moisture from the sample stream by condensing it into a liquid, a technique that results in the loss of water-soluble analytes like SO2 and HCl. This loss ultimay results in less accurate analyser measurements, a problem that is eliminated by the use of the Indi-GASS.
The Indi-GASS can be configured to condition sample streams with flow rates up to 5 litres per minute and water content up to 40 percent. The integrated filter removes particulates, while the Nafion™ dryer reduces the sample dew point to as low as -15 °C. This happens without the loss of key analytes, allowing the user to make more accurate measurements than ever before.
Indi-GASS System Spare Parts
IndiGASS ITEM | Description |
FF-250-E-2.5G | 2″ Teflon & glass replacement element only |
FF-250-3 | Replacement o-ring set, set of 3 |