NH3 3E 100 SE氨氣傳感器NH3 3E100SE
MINI 1845-932-30009
SENSORIC CLASSIC 1845-932-30069
CTL 4 series adaptation 1845-932-30049
CTL 7 series adaptation 1845-932-30079
系列 | 氣體類型 | 產(chǎn)品名稱 | 使用壽命* | 量程 | 產(chǎn)品描述 | |
Sensoric | NH3 | NH3 3E 100 | >18 months | 0-100ppm | 三電極傳感器,有機(jī)電極,有迷你型,標(biāo)準(zhǔn)型,4系和7系三種尺寸. | |
Sensoric | NH3 | NH3 3E 100 SE | >2 years | 0-100ppm | 三電極傳感器,有迷你型,標(biāo)準(zhǔn)型,4系和7系三種尺寸. | |
Sensoric | NH3 | NH3 3E 1000 | >18 months | 0-1000ppm | 三電極傳感器,有機(jī)電極,有迷你型,標(biāo)準(zhǔn)型,4系和7系三種尺寸. | |
Sensoric | NH3 | NH3 3E 1000 SE | >2 years | 0-1000ppm | 三電極傳感器,有迷你型,標(biāo)準(zhǔn)型,4系和7系三種尺寸. | |
Sensoric | NH3 | NH3 3E 500 SE | >2 years | 0-500ppm | 三電極傳感器,有迷你型,標(biāo)準(zhǔn)型,4系和7系三種尺寸. | |
Sensoric | NH3 | NH3 3E 5000 SE | >2 years | 0-5000ppm | 三電極傳感器,有迷你型,標(biāo)準(zhǔn)型,4系和7系三種尺寸. |
Sensoric NH3 3E 100 SE
FEATURES
Amperometric 3 electrode sensor cell
Very stable zero reading
Very selective
Highly sensitive
Hydrous electrolyte
TYPICAL APPLICATIONS
TLV-monitoring, leakage detection
portable & fixed point applications
Food & Refrigeration Industry, General Industry, Semiconductor Industry
TECHNICAL SPECIFICATIONS
Measuring Range 0–100 ppm
Sensitivity Range 130 nA/ppm ± 30 nA/ppm
Zero Current at 20°C < ± 100 nA
Resolution at 20°C < 1 ppm
Bias Potential 0 mV
Linearity < 10% full scale
Response Time at 20°C
t50 < 20 s calculated from 5 min. exposure time
t90 < 60 s calculated from 5 min. exposure time