ThermoTrans 210/211 德國(guó)(KNICK)科尼克 溫度變送器
隔離變送熱電隅信號(hào)、輸出0...20mA,4...20mA,0...10V,工作電壓1000V,測(cè)試電壓4kV。
Input data | Sensor type | | Range |
| | |
| Type B | DIN / IEC 584-1 | 0 … | +1820 °C |
| Type E | DIN / IEC 584-1 | –270 … | +1000 °C |
| Type J | DIN / IEC 584-1 | –210 … | +1200 °C |
| Type K | DIN / IEC 584-1 | –270 … | +1372 °C |
| Type L | DIN 43710 | –200 … | +900 °C |
| Type N | ASTM E 230-87 | –270 … | +1300 °C |
| Type R | DIN / IEC 584-1 | –50 … | +1767 °C |
| Type S | DIN / IEC 584-1 | –50 … | +1767 °C |
| Type T | DIN / IEC 584-1 | –270 … | +400 °C |
| Type U | DIN 43710 | –200 … | +600 °C |
| |
Voltage input | –20 … +100 mV |
| |
Input resistance | >10 Mohms |
| |
Span (configurable) | Min. ≥2 mV, max. measuring end – measuring start |
| |
Sensor failure monitoring | All inputs for open circuit (not with voltage measurement) |
| |
Input error limits | ±10 µV +0.05 % of meas. val. |
| |
Temperature coefficient | 0.01 %/K full scale (average TC in permitted operating temperature range, |
at input | reference temperature 23 ºC) |
| |
Reference junction input | Internal Pt 100 | <±1.0 K |
(configurable) | External Pt 100 | <±0.3 K + error of Pt 100 used |
Output data |
| |
Output signal | Model 210: 0 / 4 ... 20 mA, impressed current, load voltage ≤10 V |
(0 … 100 %) | Model 211: 0 ... 10 V, impressed voltage, load current ≤10 mA |
| |
Resolution | Approx. 8000 steps (for 0 ... 100 %) |
| |
Control range | –2.5 % ... 102.5 % of span |
| |
Overload range | Model 210: –1.0 mA or 22 mA |
with error message | Model 211: –0.5 V or 11 V |
| |
Output error limits | 0.1 % full scale |
| |
Temperature coefficient | 0.01 %/K full scale (average TC in permitted operating temperature range, |
at output | reference temperature 23 ºC) |
| |
Residual ripple at output | <10 mVpp + digitalization error of input |
Transmission behavior |
| |
Characteristic | Temperature-linear, voltage-linear or customer-specific rising or falling |
| |
Measuring rate | Approx. 1 / s |
| |
Response time T99 | ≤900 ms |
| |
Digital output filter | T99 = 0 ... 100 s (1st order filter) |
Power supply | |
| |
Power supply | 230 V AC –15 % +10 %, 48 … 62 Hz, approx. 2 VA |
| |
Option 336: | 24 V AC / DC | AC: –15 % +10 %, 48 … 500 Hz, approx. 1.5 VA |
| | DC: –15 % +20 %, approx. 1.2 W |
| |
Option 363: | 115 V AC –15 % +10 %, 48 … 62 Hz, approx. 2 VA |
Isolation | |
| |
Galvanic isolation | 3-port isolation between input, output and power supply |
| |
Test voltage | 4 kV AC (input against output and power supply) |
| 3 kV AC (output against power supply) |
| |
Working voltage | 1000 V AC/DC input against output and power supply with overvoltage category II |
(basic isolation) | and pollution degree 2, |
| 330 V AC/DC output against power supply with overvoltage category II and |
| pollution degree 1 according to EN 61010-1 |
| For applications with high working voltages, you should ensure there is sufficient |
| spacing or isolation from neighboring devices and protection against electric shocks. |
| |
Protection against electri | Safe isolation according to EN 61140 by reinforced insulation in accordance with |
shock | EN 61010-1. |
| Working voltages with overvoltage category II and pollution degree 2: |
| 600 V AC / DC for input against output and power supply |
| with overvoltage category II and pollution degree 2: |
| 300 V AC / DC for output against power supply. |
| For applications with high working voltages, you should ensure there is sufficient |
| spacing or isolation from neighboring devices and protection against electric shocks. |
Standards and approvals | |
| |
Surge withstand | 5 kV 1.2 / 50 µs according to IEC 255-4 |
| |
EMC 1) | EMC directive 89/336/EEC, EN 61326, NAMUR recommendation NE 21 |
Other data |
| |
Interface | Optical, interface adapter on RS 232 interface (PC) is included in the |
(only user-definable models) | ZU 0254 communications kit |
| |
Ambient temperature | Operation: | –10 ... +60 ºC |
| Transport and storage: | –30 ... +80 ºC |
| |
Housing | Modular housing A7, width 22.5 mm, screw terminals |
| See dimension drawings for further dimensions |
| |
Protection class | Housing IP 40, terminals IP 20 |
| |
Mounting | With snap-on mounting for 35 mm top hat rail according to EN 50022-35, |
| width 22.5 mm, See dimension drawings for conductor cross section |
| |
Weight | Approx. 300 g |
|
|
1) Slight deviations are possible while there is interference from RF radiation |