NRP/NRP2功率計在電子測試與測量領域中,精確測量射頻功率是挑戰(zhàn)性的任務之一。無論是在測量移動通信中的某個射頻模塊,或是在復雜雷達系統(tǒng)、基站或的應用中,都是需要盡可能精確的功率測量。這種要求不僅體現(xiàn)在實驗室校準應用上,同時也體現(xiàn)在研發(fā),生產(chǎn),維修等應用中。
NRP-Z系列射頻功率探頭無論在實驗室還是在生產(chǎn)線,微波功率計R&S NRP都是你正確的選擇。新穎的R&S NRP系列功率計的通用性主要歸因于新近開發(fā)的功率探頭。這些探頭是智能的獨立儀器,他們與基本單元通訊,或經(jīng)由數(shù)字接口與一個pc機通信?,F(xiàn)在實現(xiàn)的智能傳感技術,建立了根據(jù)通用性和準確性要求的新標準。
- R&S®NRP-Z11 Order No. 1138.3004.02 / 1138.3004.04Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector - R&S®NRP-Z21 Order No. 1137.6000.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z22 Order No. 1137.7506.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -57 dBm to +33 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z23 Order No. 1137.8002.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -47 dBm to +42 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z24 Order No. 1137.8502.02Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -42 dBm to +45 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z31 Order No. 1169.2400.02 / 1169.2400.04Three-Path Diode Power Sensors
Fast, accurate and packed with features for CW and modulated signals
Measurement range: -67 dBm to +23 dBm,
Frequency range: 10 MHz to 33 GHz,
3.5 mm connector
- R&S®NRP-Z211 Order No. 1417.0409.02Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector - R&S®NRP-Z221 Order No. 1417.0309.02Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
- R&S®NRP-Z51 Order No. 1138.0005.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -30 dBm to +20 dBm,
Frequency range: DC to 18 GHz,
N connector - R&S®NRP-Z52 Order No. 1138.0505.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 33 GHz,
3.5 mm connector - R&S®NRP-Z55 Order No. 1138.2008.03Thermal Power Sensor model .03
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 40 GHz,
2.92 mm connector - R&S®NRP-Z55 Order No. 1138.2008.04Thermal Power Sensor model .04
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: -35 dBm to +20 dBm,
Frequency range: DC to 44 GHz,
2.92 mm connector - R&S®NRP-Z56 Order No. 1171.8201.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 50 GHz,
2.4 mm connector - R&S®NRP-Z57 Order No. 1171.8401.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 67 GHz,
1.85 mm connector - R&S®NRP-Z58 Order No. 1173.7031.02Thermal Power Sensor
Most accurate power measurements for reference applications and use in calibration labs
Measurement range: –35 dBm to +20 dBm,
Frequency range: DC to 110 GHz,
1.00 mm connector
- R&S®NRP-Z81 Order No. 1137.9009.02Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 18 GHz,
N connector - R&S®NRP-Z85 Order No. 1411.7501.02Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.92 mm connector - R&S®NRP-Z86 Order No. 1417.0109.40Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.4 mm connector
- R&S®NRP-Z91 Order No. 1168.8004.02 / 1168.8004.04Average Power Sensor
Accurate average power measurements for EMC applications
Measurement range: -67 dBm to +23 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector - R&S®NRP-Z92 Order No. 1171.7005.02 / 1171.7005.42Average Power Sensor
Accurate average power measurements for EMC applications
Measurement range: -57 dBm to +33 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
- R&S®NRP-Z28 Order No. 1170.8008.02Level Control Sensor
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector - R&S®NRP-Z98 Order No. 1170.8508.02Level Control Sensor
Highly accurate signal level generation in conjunction with a signal generator
Measurement range: -67 dBm to +20 dBm,
Frequency range: 9 kHz to 6 GHz,
N connector
- R&S®NRP-Z27 Order No. 1169.4102.02Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 18 GHz,
N connector - R&S®NRP-Z37 Order No. 1169.3206.02Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 26.5 GHz,
3.5 mm connector
- R&S®NRPZ-K1 Order No. 1418.9800.03R&S®NRPV license for one R&S®NRP-Zxx power sensor
Convenient power measurements via PC application
- R&S®NRP-Z2 Order No. 1146.6750.03 / 1146.6750.05 / 1146.6750.10 / 1146.6750.15Sensor Extension Cable
In some cases the signal source is far away from the base unit. Therefore four different sensor extension cables are available, to get a total length of 3, 5 or 10 meters.
- R&S®NRP-Z3 Order No. 1146.7005.02USB Adapter (active)
R&S®NRP-Z3 active USB adapter has been developed for applications requiring external triggering of the power sensor. It also offers a separate power supply.
- R&S®NRP-Z4 Order No. 1146.8001.02 / 1146.8001.04 / 1146.8001.06 / 1146.8001.11USB Adapter (passive)
For all R&S®NRP-Z sensors. The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lenghths: 2.0m, 0.5m, 0.15m and 1m (for panel-mount)
- R&S®NRP-Z5 Order No. 1146.7740.02USB Sensor Hub
R&S®NRP-Z5 can host up to 4 R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.
功率計實物照片