示蹤氣體泄漏標(biāo)準(zhǔn) - 也被稱為校準(zhǔn)泄漏,泄漏標(biāo)準(zhǔn)和氦氣泄漏 - 正處于一個(gè)廣泛使用的測試應(yīng)用。下面是CTS提供的各種規(guī)格型號(hào)的描述
TP型號(hào),可在從10-9到10-2 ATM的毫升/ s的泄漏率,主要是開發(fā)真空系統(tǒng)校準(zhǔn)和氦氣泄漏探測器,在真空狀態(tài)下試驗(yàn)。該型號(hào)采用了切斷閥,允許在不刪除從測試校準(zhǔn)泄漏多方面你“零”的泄漏檢測器
CPV和CPS型號(hào)也可以流動(dòng)的幾種不同燃?xì)夥N類或從10-5到10-2泄漏率混合ATM的毫升/秒,開發(fā)準(zhǔn)確校準(zhǔn)“嗅探器”型檢漏儀
該CPS型號(hào)是一個(gè)重要的工具,它允許您檢查一個(gè)組合中示蹤氣體濃度。
CPH型號(hào)可流動(dòng)青山不等10-6氣體泄漏率幾種不同類型10-2 ATM的毫升/秒,這一模式是發(fā)展成為與超高真空系統(tǒng)和其他地方在毒氣和背景信號(hào)必須保持在*低限度的關(guān)鍵應(yīng)用程序兼容。這主要是開發(fā)真空系統(tǒng)真空校準(zhǔn)和氦氣泄漏檢測器檢測,這種模式的特點(diǎn)是全金屬關(guān)閉不刪除從測試校準(zhǔn)分水器閥門泄漏,讓你“零”的泄漏檢測器。
CP型號(hào),雖然氦通常也可流動(dòng)的范圍從10-6氣體泄漏率幾種不同類型10-2 ATM的毫升/秒,CP型號(hào)主要是在真空狀態(tài)下進(jìn)行校準(zhǔn)真空系統(tǒng)和氦氣泄漏檢測器檢測。該模型采用了切斷閥,允許在不刪除從測試校準(zhǔn)泄漏多方面你“零”的泄漏檢測器
詳細(xì)部分見以下英文說明:
Tracer Gas Model Selection Overview
Tracer gas leak standards – also referred to as calibrated leaks, leak standards and helium leaks – are used in a wide variety of test applications. Below are descriptions of the various standard models offered by CTS. |
The TP model which is available in leak rates ranging from 10-9 to 10-2 atm-cc/s was primarily developed to calibrate vacuum systems and helium leak detectors that test under vacuum. This model features a shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |
The CPV and CPS models are available flowing several different gas types or mixes in leak rates ranging from 10-5 to 10-2 atm-cc/s. The CPV and CPS models were developed to accurately calibrate “sniffer” type leak detectors. The CPS model is an essential tool which allows you to check the concentration of a tracer gas in a mix. |
The CPH model is available flowing several different gas types for leak rates ranging from 10-6 to 10-2 atm-cc/s. This model was developed to be compatible with Ultra-High vacuum systems and other critical applications where out gassing and background signals need to be kept to a minimum. It was primarily developed to calibrate vacuum systems and helium leak detectors that test under vacuum. This model features an all metal shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |
The CP model, though typically for helium is also available flowing several different gas types for leak rates ranging from 10-6 to 10-2 atm-cc/s. The CP model was primarily developed to calibrate vacuum systems and helium leak detectors that test under vacuum. This model features a shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |
The GPH model is available in leak rates ranging from 10-10 to 10-5 atm-cc/s and utilizes a reliable glass permeation type leak element. |
The GP model helium calibrated leak standard is available in leak rates ranging from 10-9 to 10-5 atm-cc/s and utilizes the same reliable glass permeation type leak element. This model features a shut off valve which allows you to “Zero” the leak detector without removing the calibrated leak from the test manifold. |