MultiTox DMI–TT6電化學(xué)有毒氣體探測儀,MultiTox DMI TT6探測器的范圍可用于廣泛的有毒氣體,并以其出色的選擇性,而聞名。對于一些應(yīng)用程序,電化學(xué)細胞是的解決辦法。MultiTox DMI TT6 也是可供氧氣檢測,并在幾個苛刻的解決方案中使用
特性:
- Electrochemical cell technology
- Built-in temperature and humidity compensation
- Hot swap sensor cartridges, “No-touch”field cabling
- Configuration and maintenance by a single technician.
- Wireless, certified configuration tool
- Available in aluminium only
- HART (R) option
- 總覽:
-
The MultiTox DMI-TT6 range of detectors are available for a wide range of toxic gases, and is known for its excellent selectivity. For some applications, electrochemical cells are the only solution. The MultiTox DMI-TT6 is also available for Oxygen detection, and is used in several demanding solutions.
The DMI-TT6 and DMI-TO6 are constructed from a common housing and electronics with the detection properties being determined by the type of sensor (cartridge) used. A wide range of cells are available, including hydrogen sulphide, ammonia and carbon monoxide to name a few. The cells are intrisically safe, and may be replaced with the detector powered. This versatile housing is also used for our flammable (catalytic) gas detector as well our semiconductor (MOS) detector - although these units are certified flameproof, not intrinsically safe - see separate datasheet.
The intelligent, microprocessor driven unit is fully configurable using a wireless handheld terminal (TLU) giving true flexibility to the installer. Elements such as relay operation and alarm levels are all set via the TLU, hazardous area approved handheld unit.
The device offers a wide range of output options as standard and is suitable for use in SIL 2 applications. The unit may be interfaced directly with a wide range of panels, controllers and PLC’s etc.
The DMI-TT6 and DMI-TO6 may be used in refineries, offshore driling and production platforms, processing and storage plants as well as chemical plants.技術(shù)參數(shù):
GENERAL Type Gas detector Product Simtronics MultiTox, H2S (EC) Product code DMI-TT6-31** Manufacturer Simtronics GAS DETECTOR Type Electrochemical cell Detected gas Hydrogen Sulphide (H2S) Calibrated range 20ppm, 50ppm, 100ppm, 200ppm (variants) PERFORMANCE Accuracy ±5% of calibrated range Linearity ±2% Repeatibility ±1% Stability ±1% (zero point) Response time T50: <30 sec, T90: <120 sec Calibration interval 3 months (calibration check) Sensor life 24 months ELECTRICAL Power supply 24V DC, range (18 - 32V DC) Power consumption 30 mA normal; 180 mA during heating Cable entry 2x M20, one entry with Exd plug Junction box “No-touch” field cabling”, detector replaceable without opening cable glands Connection 0.3 mm2 (22 AWG) - 1.5 mm2 (16 AWG), 3 or 4 wires Analogue output signal 0-20mA, source, max. load impedance 700?. Fault signalling Diagnosis signalling in the 2.0 - 3.4mA range Relays 2 configurable relays for alarm and fault Maintenance interface Wireless (IR) handheld terminal for configuration, test and diagnosis ENVIRONMENT Storage -40°C to +70°C (-40°F to 158°F) Operation -20°C to +50°C (-4°F to 122°F) ATEX -40°C to +60°C (-40°F to 140°F) Humidity 95% RH (non-condensing) Ingress IP66 RFI/EMI Complies with EN50081-1, EN50081-2, EN50082-1 and EN50082-2. HOUSING Ex Classification Ex d ia II C T6 Material Epoxy coated aluminium or Stainless steel (Specify variant) Weight Aluminium: 1.8 Kg (4.0 lbs) Stainless steel: 6.5 Kg (14.3 lbs) Dimensions 165H x 118D x 184W (mm), 6.50H x 4.65D x 7.25W (inches) APPROVALS ATEX Certificate DM LCIE 03 ATEX 6262 ACCESSORIES TLU600 Infrared remote control unit AS008-200 Sunshade AS005 Calibration cup AS011-2-X Sample flow housing AS019 Splash guard
文檔:
Product Sheet MultiTox DM TT6338.12 KB
Operating Manual MultiTox Detector2.13 MB
Operating Manual Remote Controller TLU 600/6102.93 MB
證書:
ATEX Certification402.79 KB
應(yīng)用:
Chemical Plants
Pharmaceutical Plants
Auto Industry
Onshore/Offshore Oil & Gas Platforms
Storage of Toxic Materials