重慶汗丁直銷Keithley吉時利雙通道毫微2182A型納伏表產(chǎn)品概述:
The two-channel Model 2182A Nanovoltmeter is optimized for making stable, low noise voltage measurements and for characterizing low resistance materials and devices reliably and repeatably. It provides higher measurement speed and significantly better noise performance than alternative low voltage measurement solutions. The Model 2182A represents the next step forward in Keithley nanovoltmeter technology, replacing the original Model 2182 and offering enhanced capabilities including pulse capability, lower measurement noise, faster current reversals, and a simplified delta mode for making resistance measurements in combination with a reversing current source, such as the Model 6220 or 6221.
重慶汗丁直銷Keithley吉時利雙通道毫微2182A型納伏表產(chǎn)品性能特點:
? Make low noise measurements at high speeds, typically just 15nV p-p noise at 1s response time, 40–50nV p-p noise at 60ms
? Delta mode coordinates measurements with a reversing current source at up to 24Hz with 30nV p-p noise (typical) for one reading. Averages multiple readings for greater noise reduction
? Synchronization to line provides 110dB NMRR and minimizes the effect of AC common-mode currents
? Dual channels support measuring voltage, temperature, or the ratio of an unknown resistance to a reference resistor
? Built-in thermocouple linearization and cold junction compensation
特點
優(yōu)勢
1nV 靈敏度 提供**的超低電壓測量。 1s 響應(yīng)時間下的噪聲通常只有 15nVp-p,60ms 下噪聲為 40–50nV p-p 確保在廣泛的有用響應(yīng)時間下實現(xiàn)低噪聲電平。 雙通道 支持測量電壓、溫度或未知電阻與參考電阻的比值。 測量周期與電源線交流周期同步 *小化由于線路周期不同階段的起始讀數(shù)導(dǎo)致的變化。 其結(jié)果是線路抗擾能力非常高,基本或根本不需要進(jìn)行屏蔽或濾波。 內(nèi)置熱電偶線性化和冷接點補償 簡化了進(jìn)行**溫度測量的過程。 內(nèi)部極性反轉(zhuǎn)測量技術(shù) 消除熱誤差源。 *適合用于 6220/6221 型電流源 進(jìn)行微分電導(dǎo)、脈沖和電阻測量時,允許將這兩臺儀器作為一臺單獨的儀器來運行。 與 6220 或 6221 結(jié)合使用時,支持增量模式電流反向測量技術(shù) 支持低至 10n? 的電阻測量。 2182A/6221 組合將信號脈沖與測量同步 將溫度敏感型 DUT 的功耗降至*低。
重慶汗丁直銷Keithley吉時利雙通道毫微2182A型納伏表產(chǎn)品測量模式:
Flexible, Effective Speed/Noise Trade-offs
The Model 2182A makes it easy to choose the best speed/filter combination for a particular application’s response time and noise level requirements. The ability to select from a wide range of response times allows optimizing speed/noise trade-offs. Low noise levels are assured over a wide range of useful response times, e.g., 15nV p-p noise at 1s and 40-50nV p-p noise at 60ms are typical. Figure 1 illustrates the Model 2182A’s noise performance.
Power line noise can compromise measurement accuracy significantly at the nanovolt level. The Model 2182A reduces this interference by synchronizing its measurement cycle to line, which minimizes variations due to readings that begin at different phases of the line cycle. The result is exceptionally high immunity to line interference with little or no shielding and filtering required.
Optimized for Use with Model 6220/6221 Current Sources
Device test and characterization for today’s very small and power-efficient electronics requires sourcing low current levels, which demands the use of a precision, low current source. Lower stimulus currents produce lower—and harder to measure—voltages across the devices. Linking the Model 2182A Nanovoltmeter with a Model 6220 or 6221 Current Source makes it possible to address both of these challenges in one easy-to-use configuration.
When connected, the Model 2182A and Model 6220 or 6221 can be operated like a single instrument. Their simple connections eliminate the isolation and noise current problems that plague other solutions. The Model 2182A/622X combination allows making delta mode and differential conductance measurements faster and with less noise than the original Model 2182 design allowed. The Model 2182A will also work together with the Model 6221 to make pulse-mode measurements.
The 2182A/622X combination is ideal for a variety of applications, including resistance measurements, pulsed I-V measurements, and differential conductance measurements, providing significant advantages over earlier solutions like lock-in amplifiers or AC resistance bridges. The 2182A/622X combination is also well suited for many nanotechnology applications because it can measure resistance without dissipating much power into the device under test (DUT), which would otherwise invalidate results or even destroy the DUT.
An Easy-to-Use Delta Mode
Keithley originally created the delta mode method for measuring voltage and resistance for the Model 2182 and a triggerable external current source, such as the Model 2400 SourceMeter® SMU instrument. Basically, the delta mode automatically triggers the current source to alternate the signal polarity, and then triggers a nanovoltmeter reading at each polarity. This current reversal technique
重慶汗丁直銷Keithley吉時利雙通道毫微2182A型納伏表產(chǎn)品技術(shù)規(guī)范: