the SERIES PMT2 Particulate Transmitter is designed to measure particulate emission levels from dust collector discharge. Using DC coupled electrostatic induction sensing technology, the transmitter monitors a pA current that is generated as particulate passes near the probe; a 4 to 20 mA signal will vary based on the particulate level. The PMT2 offers 6 sensitivity ranges allowing the user to choose the range that will best fit the application. The range and test selector switch can also be set to output a 4 mA or 20 mA signal to assist with set up or trouble shooting. Averaging time setting can be used to dampen the signal if desired.
Service:
Air and compatible gases, any type of particulate conductive or nonconductive.
Wetted Materials:
316L SS, silicone, and PTFE.
Enclosure:
Powder coated aluminum.
Accuracy:
±5% of reading.
Particulate Size:
0.3 microns and higher.
Detection Range:
5 to 5000 pA (6 selectable range options).
Temperature Limits:
Ambient: -40 to 145°F (-40 to 63°C); Process: -40 to 248°F (-40 to 120°C).
Pressure Limit:
30 psi (2 bar).
Output Signal:
4 to 20 mA.
Power Requirements:
12 to 28 VDC.
Electrical Connection:
Two 1/2" female NPT conduit openings.
Terminal Block:
Removable (16 to 20 AWG wire).
Process Connection:
See model chart on catalog page.
Probe Lengths:
See model chart on catalog page.
Enclosure Rating:
Type 4 (IP66).
Mounting Orientation:
Any.
Averaging Time:
1 to 360 s (10 selectable options).
Weight:
Varies with length of probe and type of mount.
Agency Approvals:
CE, cULus; ATEX Compliant: 0518 II 1 G Ex ia IIB T4 GA (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C) / II 1 D Ex ia IIIC T120°C Da (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C). Type Certificate No.: DEMKO 16ATEX1768 X. ATEX Standards: EN 60079-0:2012/A11:2013; EN 60079-11:2012. IECEx Certified: Ex ia IIB T4 Ga (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C) / Ex ia IIIC T120°C Da (-40°C ≤ Tamb ≤ 63°C) (-40°C ≤ T Process ≤ 120°C). Certificate of Conformity: IECEx UL 16.013X. IECEx Standards: IEC 60079-0: 2011; IEC 60079-11: 2011. UL Listed Intrinsically Safe for Class I, Groups C and D; Class II, Groups E, F and G; Class III; Class I Zone 0 AEx ia IIB T4 Ga; Class I Zone 0 Ex ia IIB T4 Ga.
ModelDescription
PMT2-03-A-U2 Particulate transmitter, 3" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections
PMT2-05-A-U2 Particulate transmitter, 5" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections
PMT2-10-A-U2 Particulate transmitter, 10" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections
PMT2-15-A-U2 Particulate transmitter, 15" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections
PMT2-20-A-U2 Particulate transmitter, 20" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections
PMT2-30-A-U2 Particulate transmitter, 30" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections
PMT2-36-A-U2 Particulate transmitter, 36" probe, UL intrinsically safe rating, 3/4" male NPT process connections, 1/2" female NPT electrical connections