一、產(chǎn)品簡介:
粒化電爐磷渣容重測定儀是石膏檢測儀器,主要用于建筑石膏松散容重測定的儀器,產(chǎn)品符合GB9776標(biāo)準(zhǔn)要求。使用前務(wù)必仔細(xì)閱讀說明書。并由**實驗人員操作,以避免操作不當(dāng)引起的傷害。如需了解更多資料請與我公司客服人員聯(lián)系。
1. Product introduction: Loose bulk density meter gypsum detection equipment, mainly for construction equipment Gypsum loose bulk density of standard products meet GB9776. Be sure to read the instructions carefully before use. It is operated by **experimental personnel to avoid injury caused by improper operation. For more information, please contact our customer service staff.
二、產(chǎn)品結(jié)構(gòu):
由1.錐形篩。2.三腳支架。3.測量容器(上部是延伸筒、下部是容重桶,其容量是1升)三部分組成。
2. Product structure: By 1. Cone screen. 2. Tripod. 3. The measuring container (the upper part is an extension cylinder, the lower part is a bulk density bucket, and its capacity is 1 liter) consists of three parts.
三、主要參數(shù):
★容重桶:容積1L。
★漏斗為不銹鋼
★支架直徑為8mm圓鋼
★底盤為2mm厚不銹鋼
★底盤、漏斗和支架可以焊接和鉚接
★漏斗口下表面距容重桶上表面為100mm/不銹鋼材
★錐形篩孔徑:2mm,
★凈重:30kg。
3. Main parameters: ★ Density bucket: 1L in volume. ★The funnel is stainless steel ★Stent diameter is 8mm round steel ★The chassis is 2mm thick stainless steel ★The chassis, funnel and bracket can be welded and riveted ★The bottom surface of the funnel mouth is 100mm/stainless steel from the top surface of the bulk density barrel ★Aperture of cone screen: 2mm, ★Net weight: 30kg.
四、使用方法:
★從保存在密封容器內(nèi)的試驗室石膏樣品中,取出1000克試樣,并充分?jǐn)嚢杈鶆?,使其通過孔徑為2毫米的錐形篩,然后按下述步驟用同一儀器測定兩次。
稱量不帶延伸套筒的容重桶,精確至0.1克,在容重桶上裝上套筒,并將其放在儀器的錐形漏斗下,將試樣以100克為一份倒入漏斗中,用毛刷攪動試樣,使其通過篩網(wǎng)落入容重桶中。當(dāng)裝有延伸套簡的容重桶填滿時,在避免振動的情況下移去套筒,用直尺刮平表面,除去多余物料,直至表面與容重桶上緣位于同一水平面上為止。稱量容重桶和試樣重量精確至0.1克。
★結(jié)果的表示方法:
按下式計算松散容重,克/升
r=m1-m0
其中:m1是容重桶和試樣的重量(克)
m0是容重桶本身的重量(克)
如果兩次測定結(jié)果之差,小于兩次試驗結(jié)果較小值的5 % ,則以平均值作為試樣的松散容重;否則,應(yīng)再次測定,至兩次測定值之差小于5 %。再取其平均值。
4. How to use: ★Take out 1000 g of gypsum sample from the laboratory gypsum sample stored in a sealed container and stir it evenly to pass it through a cone-shaped sieve with an aperture of 2 mm, and then use the same instrument to measure twice as follows. Weigh the bulk density bucket without extension sleeve to the nearest 0.1 g, install the sleeve on the bulk density bucket, and place it under the conical funnel of the instrument, pour the sample into the funnel in 100 g portions, Stir the sample with a brush to make it fall through the screen into the bulk density bucket. When the bulk density bucket with the extension sleeve is full, remove the sleeve while avoiding vibration, and use a ruler to smooth the surface to remove excess materials until the surface and the upper edge of the bulk density bucket are on the same level. Weigh the bulk density barrel and the sample weight to the nearest 0.1 g. ★Expression of results: Calculate loose bulk density by the following formula, g/l r=m1-m0 Among them: m1 is the weight of the bulk density barrel and the sample (g) m0 is the weight of the bulk density bucket (g) If the difference between the two measurement results is less than 5% of the smaller value of the two test results, the average value shall be used as the loose bulk density of the sample; otherwise, it shall be measured again until the difference between the two measurement values is less than 5%. Then take the average value.
五、使用安放:
本儀器應(yīng)安放在無震源無腐蝕介質(zhì)的環(huán)境中,并置于適當(dāng)高度的平臺上。必要時可調(diào)整三腳支 架下部的三個錐形螺母使其至水平位置。
Five, use and place: The instrument should be placed in an environment with no seismic source and no corrosive media, and placed on a platform with an appropriate height. If necessary, adjust the three conical nuts on the lower part of the tripod to a horizontal position.
六、維護(hù)保養(yǎng):
★用后清理、抹干凈;
★篩網(wǎng)上放干燥劑。
6. Maintenance: ★Clean up and wipe clean after use; ★Put desiccant on the screen.