氟塑料絕緣硅橡膠護(hù)套高溫電力電纜
氟塑料絕緣硅橡膠護(hù)套高溫電力電纜
Fluroplastic insulation silicon rubber sheath high-temperature power cable
執(zhí)行標(biāo)準(zhǔn)
utive standard
Q/HYDL13-2012
Q/HYDL13-2012
適用范圍
Applications
本產(chǎn)品具有耐高溫、耐低溫、柔軟、耐腐蝕等特點(diǎn),適用于發(fā)電、冶金、化工、石油等工礦企業(yè),在0.6/KV及以下惡劣環(huán)境中連接工業(yè)移動(dòng)式電氣設(shè)備傳輸電力線路用。 | The products have the features of resisting high and low temperature,anti-corrosion and softness.They are used as power transmission and distribution lines of 0.6/1KV under bad environment in the electric generation,petrol-chemical and oil industries. |
使用特性
Working features
1、額定電壓:Uo/U為0.6/1KV。 2、電纜導(dǎo)體的長(zhǎng)期允許工作溫度不超過200℃ 3、電纜的敷設(shè)溫度不低于: 固定敷設(shè)-60℃ 非固定敷設(shè)-20℃ 4、推薦的允許彎曲半徑: 無鎧裝層的電纜,應(yīng)不小于電纜外徑的6倍。 電力電纜應(yīng)不小于電纜外徑的10倍。 有鎧裝結(jié)構(gòu)的電纜,應(yīng)不小于電纜外徑的 12倍。 | 1、Rated voltage Uo/U:0.6/1KV. 2、The allowable working temperature during long period 200℃. 3、The ambient temperature should not be lower than: -60℃ for fixed cable laying. -20℃ for temporary cable laying. 4、Recommended allowable bending radius: Should be not be smaller than 6×cable diameter for cables without steel armoring layer. Should be not be smaller than 10×cable diameter for power cables. Should be not be smaller than 12×cable diameter for cables with steel armoring layer. |
電纜型號(hào)、名稱
Model and name
型號(hào) Model | 名 稱 Name | 主要使用范圍 Application |
YGC-F46 | 銅芯氟塑料絕緣硅橡膠護(hù)套高溫電力電纜 Cu Fluroplastic insulation silicon rubber sheath high-temperature power cable | 敷設(shè)在室內(nèi)、電纜溝、管道固定場(chǎng)合 Laid-up indoors,cbale channels,and in the pipes |
YGC-F46-22 | 銅芯氟塑料絕緣硅橡膠護(hù)套鋼帶鎧裝高溫電力電纜 Cu Fluroplastic insulation silicon rubber sheath steel-tape armoring high-temperature power cable | 敷設(shè)在室內(nèi)、電纜溝、管道、直埋等能承受較大機(jī)械外力等固定場(chǎng)合 Laid-up indoors,cbale channels,and buried underground,withstanding big mechanical outside force |
YGC-F46R | 氟塑料絕緣低煙低鹵阻燃聚氯乙烯護(hù)套高溫電力電纜 Fluroplastic insulation low-smoke and low-halogen flame-retardant PVC sheath high-temperature power cable | 敷設(shè)在室內(nèi)移動(dòng)要求柔軟等場(chǎng)合 Laid-up indoors and mobile |
規(guī)格、結(jié)構(gòu)
Struture
芯數(shù)×標(biāo)稱截面Core no.×section (mm2) | 導(dǎo)體種類Conductor type | F46絕緣標(biāo)稱厚度 Insulation thicdness(mm) | 保護(hù)層厚度 Protection thicdness(mm) | 電纜近似外徑 Cable outer dia.(mm) | ||
YGC-F46 | YGC-F46R | YGC-F46-22 | ||||
3×4 | B | 0.5 | - | 11.4 | - | 15.2 |
3×6 | B | 0.6 | - | 13.5 | - | 16.7 |
3×10 | B | 0.8 | 1.0 | 20.4 | 16.1 | 23.4 |
3×16 | B | 1.0 | 1.0 | 24.4 | - | 27.4 |
3×16 | R | 1.2 | - | - | 19.2 | - |
3×25 | B | 1.2 | 1.2 | 29.2 | - | 32.2 |
3×25 | R | 1.2 | - | - | 23 | - |
3×35 | B | 1.2 | 1.2 | 32.7 | - | 35.7 |
3×35 | R | 1.2 | - | - | 26.5 | - |
3×50 | B | 1.2 | 1.2 | 36.5 | - | 39.5 |
3×50 | R | 1.2 | - | - | 29.3 | - |
3×70 | B | 1.2 | 1.2 | 40.4 | - | 44.8 |
3×70 | R | 1.2 | 1.2 | - | 43.5 | - |
3×95 | B | 1.2 | 1.2 | 45.5 | - | 49.9 |
3×120 | R | 1.2 | 1.2 | - | 47.2 | - |
3×120 | B | 1.2 | 1.4 | 52.8 | - | 57.2 |
3×150 | R | 1.2 | 1.4 | - | 53.7 | - |
3×150 | B | 1.2 | 1.6 | 59.0 | - | 63.4 |
3×185 | R | 1.2 | 1.6 | - | 64.5 | - |
3×185 | B | 1.2 | 1.6 | 65.0 | - | 69.4 |
3×240 | R | 1.2 | 1.8 | - | 67 | - |
3×240 | B | 1.2 | 2.0 | 74.3 | - | 82.6 |
3×4+1×2.5 | R | 0.5 | 2.0 | - | 78.2 | - |
3×4+1×2.5 | B | 0.5 | - | 11.3 | - | 14.3 |
3×6+1×4 | R | 0.6 | - | - | 12.4 | - |
3×6+1×4 | B | 0.6 | - | 12.7 | - | 15.7 |
3×10+1×6 | R | 0.8 | - | - | 13.9 | - |
3×10+1×6 | B | 0.8 | 1.0 | 21.5 | - | 24.5 |
3×16+1×10 | R | 1.0 | - | - | 24.8 | - |
3×16+1×10 | B | 1.2 | 1.0 | 25.8 | - | 28.8 |
3×25+1×16 | R | 1.2 | - | - | 30 | - |
3×25+1×16 | B | 1.2 | 1.2 | 31.8 | - | 34.8 |
3×35+1×16 | R | 1.2 | - | - | 36.2 | - |
3×35+1×16 | B | 1.2 | 1.2 | 34.4 | - | 37.4 |
3×50+1×25 | R | 1.2 | - | - | 40.8 | - |
3×50+1×25 | B | 1.2 | 1.2 | 38.5 | - | 42.9 |
3×70+1×35 | R | 1.2 | - | - | 44.5 | - |
3×70+1×35 | B | 1.2 | 1.2 | 43.7 | - | 48.1 |
3×95+1×50 | R | 1.2 | 1.2 | - | 51.7 | - |
3×95+1×50 | B | 1.2 | 1.2 | 49.0 | - | 53.2 |
3×120+1×70 | R | 1.2 | 1.2 | - | 57.1 | - |
3×120+1×70 | B | 1.2 | 1.4 | 55.7 | - | 60.1 |
3×150+1×70 | R | 1.2 | 1.4 | - | 64.7 | - |
3×150+1×70 | B | 1.2 | 1.6 | 60.3 | - | 64.0 |
3×185+1×95 | R | 1.2 | 1.6 | - | 75.0 | - |
3×185+1×95 | B | 1.2 | 1.8 | 65.4 | - | 69.1 |
3×240+1×120 | R | 1.2 | 1.8 | - | 77.9 | - |
注:1、對(duì)于B類絕緣線芯截面在10 mm2以上和R類絕緣線芯截面在50 mm2以上的軟電纜絕緣層允許采用阻燃保護(hù)層形式,以加強(qiáng)電纜的機(jī)械性能。
Note:1.For insulation class B cable more than 10 mm2 and Class R cable more than 50 mm2,the flame-retardant protection layer should be applied to strength the mechanical property.
2、為了考慮電纜機(jī)械性能和安裝方便,對(duì)于大規(guī)格電纜可采用另加阻燃護(hù)套方式進(jìn)行防護(hù)。
For big cables,the additional flame-retardant sheath is applied for easy installation.
3、根據(jù)用戶需要,可以生產(chǎn)2芯、4芯、5芯電纜。
2-core,4-core and 5-core cables are producible as producible as per repuest.
主要技術(shù)指標(biāo) Main technical index
標(biāo)稱截面 Section area (mm2) | 導(dǎo)體結(jié)構(gòu) Conductor structure | 20℃時(shí)導(dǎo)體電阻(Ω/km)不大于 Conductor resistance at 20℃ not more than | 交流電壓試驗(yàn) AC voltage test | ||
種類 Type | 根數(shù)/單絲直徑 No./single wire dia(mm) | 不鍍錫 Non tin-plated | 鍍錫 Tin-plated | ||
4 | A | 1/2.25 | 4.61 | 4.7 | 3.5 KV 5min不擊穿 3.5 KV 5min No breakthrough |
4 | B、R | 7/0.85,19/0.52 | 4.61 | 4.7 | |
6 | A | 1/2.76 | 3.08 | 3.11 | |
6 | B、R | 7/1.04,19/0.64 | 3.08 | 3.11 | |
10 | B、R | 7/1.35,49/0.52 | 1.83 | 1.84 | |
16 | B、R | 7/1.7,84/0.49 | 1.21 | 1.24 | |
25 | B、R | 7/2.14,98/0.58 | 0.727 | 0.734 | |
35 | B、R | 7/2.52,133/0.58 | 0.524 | 0.529 | |
50 | B、R | 19/1.78,133/0.68 | 0.387 | 0.393 | |
70 | B、R | 19/2.14,133/0.68 | 0.27 | 0.277 | |
95 | B、R | 19/2.52,259/0.68 | 0.197 | 0.210 | |
120 | B、R | 24/2.52,608/0.50 | 0.161 | 0.164 | |
150 | B、R | 37/2.52,756/0.50 | 0.129 | 0.132 | |
185 | B、R | 37/2.52,427/0.74 | 0.0991 | 0.100 | |
240 | B、R | 61/2.52,427/0.85 | 0.0754 | 0.0762 |
產(chǎn)品結(jié)構(gòu)圖 Structure
型號(hào)說明 Model explanation
項(xiàng)目 Item | 代號(hào) Code | 說明 Explanation |
系列代號(hào) Series no. | Y | 移動(dòng)式電器設(shè)備等用電纜 Mobile equipment cable |
結(jié)構(gòu)代號(hào) Conductor code | C | 重型 Hesvy duty |
導(dǎo)體代號(hào) Conductor code | T X | 銅導(dǎo)體(省略)Cu(omitted) 鍍錫導(dǎo)體Tin-plated conductor |
絕緣材料代號(hào) Insulation material code | F | 聚全氟乙丙烯 (F46) |
護(hù)套材料代號(hào) Sheath material code | G | 硅橡膠 Silicon rubber |
導(dǎo)體種類 Conductor type | A B R | 單股導(dǎo)體X(可省略)Single core(omittde) 七股絞合導(dǎo)體7-core strands conductor 多股軟導(dǎo)體Multi-core strands conducto |
交貨長(zhǎng)度
Length for delivery
無鎧裝電纜允許長(zhǎng)度不小于500米,鎧裝電纜允許長(zhǎng)度不小于200米。允許長(zhǎng)度不小于30米短段電纜交貨,其數(shù)量應(yīng)不超過交貨總長(zhǎng)度的10%。 其它交貨長(zhǎng)度應(yīng)根據(jù)雙方協(xié)議長(zhǎng)度交貨。 | For cable without armoring,the delivery length is not less than 500m,and for cable with armoring,the delivery length is not less than 200m.30m length is available,but the total amount should not more than 10% of the delivery length. Other length is as per agreement. |