花30秒詢價,你會知道什么叫優(yōu)勢;花60秒咨詢,你會知道什么叫服務;
合作一次,你會知道什么叫質量!以質量求生存,以信譽求發(fā)展。我將提供*的質量,服務作為自已zui重要的責任。
有您的信任才有我的明天。期待你的詢價!!!
上海勵輝自動化科技有限公司
24小時
在 線 商 務
直線銷售 電 話:
傳 真:
聯 系 人: 陳寶全 (銷售工程師) 歡迎詢價
上海勵輝自動化科技有限公司在經營活動中精益求精,具備如下業(yè)務優(yōu)勢:
上海勵輝*低價銷售西門子PLC,200,300,400,1200,西門子PLC附件,西門子電機,西門子人機界面,西門子變頻器,西門子數控伺服,西門子總線電纜現貨供應,咨詢系列產品,折扣低,貨期準時,并且備有大量庫存. *有效
西門子數控伺服系統(tǒng):802C S、802D SL、810D DE、820D SL、840C CE、840D DE、840D SL、840Di SL、S120數控 系 統(tǒng)、數 控 伺 服 驅 動 模 塊、控 制 模 塊、電 源模 塊、備 品 備 件 等。
本公司產品質量按西門子原廠質量標準,產品質保一年,按西門子原廠包裝標準,西門子原裝*,按廠家執(zhí)行標準,需方收到貨后七日內可提出異議?。?!
我們賣的不是價格,賣的是誠信賣的是品質。
優(yōu)惠雖易,質量不易,且買且珍惜。
- Software for connecting PCs/programming devices and notebooks to programmable controllers
- Communication services:
- PROFIBUS DP master Class 1 and 2 with acyclic expansions
- PROFIBUS DP slave
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE) based on the FDL interface
- The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communications software
Benefits
- Maximum transparency due to integrated communication with SIMATIC via PROFIBUS and OPC as the standard interface
- Low-cost connection
- as PROFIBUS DP master class 1 or master class 2 with SOFTNET-PB DP
- as PROFIBUS DP slave with SOFTNET-PB DP slave
- to S7 communication with SOFTNET-PB S7
- Simple and low-cost commissioning thanks to uniform procedure and configuration functionality with NCM PC and STEP 7
Area of application
With SOFTNET for PROFIBUS, PCs can be connected to programmable controllers, such as SIMATIC S7, over PROFIBUS.
The following user interfaces are available:
- DP protocol
- PG/OP communication for SIMATIC S7
- S7 communication
- Open communication (SEND/RECEIVE) based on the FDL interface
SOFTNET is available for the following interfaces:
- CP 5612 (PCI, 32 bit)
- CP 5622 (PCIe x1)
- CP 5711 (USB V2.0)
The operating systems that are supported are listed in the ordering data for the SOFTNET software.
Functions
Software for DP protocol (SOFTNET-PB DP)
- DP Master Class 1
SOFTNET-PB DP offers DP master class 1 functionality. The central controller exchanges information with the DP slaves (e.g. ET 200S) in a specified, constantly repeating message cycle. The OPC programming interface provides the PC programmer with function calls for data transfer. The DP interface also provides the SYNC and FREEZE functions as well as activation and deactivation of slaves.
The DP function expansions for masters of Class 1 make it possible to perform read and write functions (DS_READ, DS_WRITE) as well as acknowledgement of alarms (ALARM_ACK) at the same time as processing cyclic data communication. Data that are to be transferred in acyclic mode (e.g. parameterization data) are only rarely changed in comparison to the cyclic measured values, and are transferred at lower priority in parallel with the cyclic high-speed user data transfer. Alarm acknowledgement by the master ensures reliable transfer of the alarms from DP slaves.
- DP Master Class 2
In addition to DP master Class 1 services, SOFTNET-PB DP also provides DP Master Class 2 services. Devices of this type are used (programming, configuration or control devices) during start-up, for configuring the DP system or for controlling the plant during normal operation (diagnostics). The DP programming interface provides the following services: Reading master diagnostics, slave diagnostics, inputs/outputs of a slave, configuration data and modifying slave addresses. These extended DP functions comprise non-isochronous access to the parameters and measured values of a slave (e.g. field devices of process automation and inligent HMI devices). This type of slave must be supplied with extensive parameter data during start-up and during normal operation (DS_READ, DS_WRITE).
- DP slave (SOFTNET-PB DP slave)
A DP slave is an I/O station that reads in input data and transfers output data to the I/O. The volume of input and output information is determined by the user application and can be a maximum of 122 bytes each. For the slave interface, a simple example GSD file is provided that can be adapted by the user to the slave application. This GSD file can be configured using any configuration tool which complies with the PROFIBUS DP specification IEC 61158/EN 50170, e.g. STEP 7 or NCM PC.
Software for PG/OP communication
Special programming device packages are not required because the drivers are included in the STEP 7 scope of supply.
Software for S7 communication (SOFTNET-PB S7)
SIMATIC S7 system components communicate with each other using S7 communication functions. The S7 programming interface provides programming device/PC user programs with access to SIMATIC S7 system components. This provides easy, flexible access to the data of the SIMATIC S7 controller.
The following services are available with S7 communication:
Administrative services
- Connection management
- Mini database
- Trace
Data transfer services
- Read/write variables
- BSEND/BRECEIVE (up to 64 KB per task)
Software for open communication (SEND/RECEIVE based on the FDL interface)
This interface based on Layer 2 is used for communication between
- PG/PC and SIMATIC S5
- PG/PC and SIMATIC S7
- PG/PC and PG/PC
used
SEND/RECEIVE offers the following services:
- Management services
- Connection establishment services
- Data transfer services
This interface is included in SOFTNET-PB DP and SOFTNET-PB S7. No configuration is necessary.
User interfaces
- OPC interface
The OPC server included in the respective software package can be used as the standard programming interface for the PROFIBUS DP, open communication and S7 communication protocols for linking automation technology applications to OPC-capable Windows applications (Office, HMI systems, etc.).
Mode of operation
With SOFTNET, the complete protocol stack is processed in the PC.
This architecture means that in contrast to the CP 5613 or CP 5614 products, the performance of the SOFTNET packages is dependent on the configuration or loading of the PC used.
Configuration
- The S7 communication protocol, open communication protocol and DP protocol are configured in STEP 7/NCM PC V5.1 + SP2 and higher.
- A configuration tool is included in the scope of delivery of the PROFIBUS software packages.
Technical Specifications
Performance data | CP 5612/CP 5622/CP 5711 |
---|---|
Mono protocol mode |
|
Number of connectable DP slaves | max. 60 |
Number of FDL tasks waiting | max. 50 |
Number of PG/OP and S7 connections | max. 8 |
| DP-V0, DP-V1 with SOFTNET-PB DP |
| DP-V0, DP-V1 with SOFTNET-PB DP slave |