ABB保護模塊SACE PR112/P ABB空氣開關的脫扣器多少錢 原裝正品
微處理器脫扣器整定范圍:
空氣斷路器 - Emax
脫扣器(PR121/P、PR122/P及PR123/P)
對于PR121/P保護脫扣器:
過載長延時整定(L) I1 = 0.4~1.0×In 步距為0.025×In
t1 = 3-12-24-36-48-72-108-144s (3×I1時)
選擇性短路短延時整定(S)
(可關斷)
I2 = 1-1.5-2-2.5-3-3.5-4-5-6-7-8-8.5-9-9.5-10×In
t2 = 0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8s (I2 t = k, t = k可選)
瞬時短路整定(I) (可關斷) I3 = 1.5-2-3-4-5-6-7-8-9-10-11-12-13-14-15×In
接地故障整定(G) (可關斷) I4 = 0.2-0.3-0.4-0.6-0.8-0.9-1.0×In
t4 = 0.1-0.2-0.4-0.8s (I2 t = k, t = k可選)
對于PR122/P保護脫扣器:(L和S有熱存儲記憶功能;S和G有區(qū)域選擇功能)
過載長延時整定(L) I1 = 0.4~1.0×In 步距為0.01×In t1 = 3~144s 步距為3s (3×I1時)
選擇性短路短延時整定(S)
(可關斷)
I2 = 0.6~10×In 步距為0.1×In t2 = 0.05~0.8s 步距為0.01s (I2 t = k, t = k(可選)
瞬時短路整定(I) (可關斷) I3 = 1.5~15×In 步距為0.1×In 瞬時
接地故障整定(G) (可關斷) I4 = 0.2~1.0×In 步距為0.02×In t4 = 0.1~1.0s 步距為0.05s (I2 t = k, t = k(可選)
剩余電流保護(Rc) (可關斷) Id = 3-5-7-10-20-30 A td = 0.06-0.1-0.2-0.3-0.4-0.5-0.8s
超溫保護(OT) 70°C報警,85°C脫扣 瞬時
相不平衡保護(U) (可關斷) I6 = 5%~90%×In 步距為5% t6 = 0.5~60s 步距為0.5s
ABB保護模塊SACE PR112/P 現(xiàn)貨
ABB空氣開關的脫扣器多少錢
類型:
PR121/P:基本型
PR122/P:液晶顯示
PR123/P:高級型
主要特點:
? 運行時不需外部電源
? 采用微處理器技術
? 精密度高
? 對電流的真實值R.M.S反應靈敏
? 故障原因指示以及脫扣數(shù)據(jù)記錄
? 各型號的脫扣器可互換
? 中性線的設定情況:
- 可設定為OFF或相電流的50%、或200%,應用于E1、
E2、E3、E4/f、E6/f,以及帶外部中性線保護的E4和E6
- 可設定為OFF或相電流的50%,應用于E4和E6
各種脫扣器的功能如下:
ABB保護模塊SACE PR112/P 一級代理商
? 這里有原裝正品的..