Heat resistance is good, the flow rate is two times of the conventional steel core aluminum wire. In the transformation, rod tower case can be re set up new. Carbon fiber composite core aluminum stranded wire in the cross-sectional area ratio of steel core aluminum stranded wire more than 29%. ACCC conductor can operate effectively at high temperature of 200 degrees C, and the temperature of conventional steel core aluminum stranded wire (ACSR) is 100. Therefore, especially in the heavy snow disaster occurs, by improving the current carrying capacity of transmission lines, the conductor temperature increases, the melting of snow cover on the transmission line, can influence from ice to maximize the protection of transmission lines.
Strength of 2 times the ordinary wire. The tensile strength of ordinary steel is 1240MPa~1410MPa, while the ACCC wire carbon fiber mixed curing mandrel, is two times that of the former. Therefore, when the ice on the transmission line, can withstand the weight of two times the ordinary wire, greatly increased the weight of the wire.
導(dǎo)電率高,節(jié)能6%。由于ACCC導(dǎo)線不存在鋼絲材料引起的磁損和熱效應(yīng),而且在輸送相同負(fù)荷的條件下,具有更低的運(yùn)行溫度,可以減少輸電損失約6%
High conductivity, energy saving 6%. Because the ACCC wire does not have the magnetic loss and heat effect caused by the wire material, and has lower operating temperature under the condition of conveying the same load, the transmission loss can be reduced by about 6%
Low sag, lower than 2 times the sag. Compared with ACCC and ACSR conductor has low sag characteristics, under the condition of high temperature sag to ACSR 1/2, can effectively reduce the space overhead insulation corridor, improve the security and reliability of the wire running.
Light weight 10~20%. The proportion of ACCC wire is about 1/4 of steel. Under the same outer diameter, the aluminum section of ACCC is 1.29 times of the conventional ACSR wire. ACCC unit length weight than the conventional ACSR wire light 10~20%, showing the advantages of light weight ACCC. The weight of their own to reduce, but also increase the carrying capacity of its in snow and ice.
Corrosion resistance, the service life of 2 times higher than ordinary wire. Carbon fiber composite material and environmental affinity, while avoiding the problem of galvanic corrosion between the conductor wire when energized and galvanized steel wire, effectively delaying wire aging, 2 times higher than ordinary wire service life. Can recycle.
Same capacity line investment cost is lower than ordinary wire. Because the ACCC wire double capacity operation, and high tensile strength, low sag, light weight and other characteristics, can make the span between the rod and the tower increases, reduced height, reduced by 20% of the tower, saving land, the same line capacity than ordinary wire low cost.
To save half of the consumption of aluminum. According to the annual power circuit 2 million tons of aluminum consumption, can save nearly 1 million tons of aluminum. To protect the environment and improve the ecological environment, it has the significance of the epoch.