国产精品成人网站,亚洲欧美精品在线,色一情一乱一伦,又大又紧又粉嫩18P少妇

服務(wù)咨詢

產(chǎn)品求購企業(yè)資訊會展供應(yīng)

發(fā)布詢價單
儀表網(wǎng)>產(chǎn)品庫>測量/計(jì)量>其它測量>其它測量>腦細(xì)胞熒光顯微系統(tǒng)
  • 腦細(xì)胞熒光顯微系統(tǒng)

MapAnalyzer 腦細(xì)胞熒光顯微系統(tǒng)

參考價
面議
具體成交價以合同協(xié)議為準(zhǔn)
  • 型號MapAnalyzer
  • 品牌
  • 所在地
  • 更新時間2021-09-28
  • 廠商性質(zhì)經(jīng)銷商
  • 入駐年限1
  • 實(shí)名認(rèn)證已認(rèn)證
  • 產(chǎn)品數(shù)量1258
  • 人氣值2934
產(chǎn)品標(biāo)簽

客服在線 索取相關(guān)資料 在線詢價

聯(lián)系方式:銷售 查看聯(lián)系方式

聯(lián)系我們時請說明是 儀表網(wǎng) 上看到的信息,謝謝!

同類產(chǎn)品
 安捷來的經(jīng)營理念:高品質(zhì)創(chuàng)造高價值,用高品質(zhì)的產(chǎn)品和服務(wù)為客戶創(chuàng)造*大的科研及商業(yè)價值。安捷來勒一貫以“科技保證質(zhì)量,服務(wù)完善產(chǎn)品”為宗旨,以廣泛深厚的國際關(guān)系、強(qiáng)大的營銷和售后服務(wù)力量、雄厚的技術(shù)實(shí)力,為優(yōu)異科研領(lǐng)域提供歐美、日本等高性能的,在世界范圍內(nèi)采取*新技術(shù)生產(chǎn)的10,000余種科研儀器設(shè)備及理想的研究、生產(chǎn)技術(shù)環(huán)境,其產(chǎn)品廣泛應(yīng)用于電子、半導(dǎo)體、醫(yī)藥、化工、化妝品、涂料、石油、食品等行業(yè)及高校、檢驗(yàn)檢疫局、商檢、藥檢、軍科院、中科院等科研機(jī)構(gòu)。經(jīng)過10年的經(jīng)驗(yàn)積累,安捷來勒能夠?yàn)榭蛻籼峁㊣T、半導(dǎo)體、醫(yī)藥、化工、食品等行業(yè)產(chǎn)品檢測及品質(zhì)管理的整體實(shí)驗(yàn)室解決方案和專業(yè)化服務(wù)。
點(diǎn)擊展示更多內(nèi)容
腦細(xì)胞熒光顯微系統(tǒng)
腦細(xì)胞熒光顯微系統(tǒng) 產(chǎn)品詳情

腦細(xì)胞熒光顯微系統(tǒng):

Mapping FluorescenceMicrophotometry System
MapAnalyzer

Bringing new techniques to your research.




In addition to conventionalobservation and photomicrographic techniques, the quantitative andqualitative analysis of specimen through microphotometry is moreand more in demand. In the medical and biological fields,microphotometry is established technique for quantitative analysisof various intercellular substances.
MapAnalyzer was developed for quantitative microanalysis ofdistribution of various substances, such as neurotransmitters andneuromodulators, in the large tissue slice. With Yamato ScientificCo.fs MapAnalyzer, the possibilities of your research will beextended.

- Application -
(1)Quantitative analysis of immunohistochemical fluorescence
Distribution of substances in animal and human slices
Detection of abnormal changes of substances in diseased tissues
Detection of effect of drugs on the central nervous system and others in the animal experiments
Elimination of non-specific autofluorescence
Comparison analysis among various substances in the same slice
(2)Quantitative analysis of enzyme-labelled immunohistochemistryand various histochemistry
(3)Measurement of fluorescence chelating agent or fluorescenceligand
(4)Quantitative analysis of DNA or RNA
(5)Quantitative analysis of autoradiographs or X-ray film
(6)Cytotoxicity testing
Quantitative immunohistochemicaldistribution
of calmodulin-dependent protein kinase II in the
coronal slice of a rat brain.

An image of the quantitativedistribution of a substance can be obtained as follows: (1) thetarget substance labeled by immunofluorescent staining in amicroarea of a slice is illuminated by a fine excitation beam (theminimum diameter on a slice is 5 µm) which is narrowed by a fielddiaphragm and aperture diaphragm; (2) the fluorescence in this areais collected into the photometer by the objective lens through aphotometry diaphragm, and its intensity is measured; (3) the sliceis moved by a two-dimensional scanning stage (the maximum stagemotion is 140 mm x 140 mm), and the fluorescence intensity in thenext microarea is measured; (4) the measured fluorescence intensityin each microarea is collected in a host computer, where it isanalyzed for reconstruction of an image of the entire scanned area;and (5) the image can be viewed as a close-up, in full or at anangle, and displayed quantitatively as a colored or monochromaticimage. The actual intensity in a specific region is displayed whenthat region is selected by a cursor on the image on a TV monitor.
A second halogen lamp and a band-pass filter of variouswavelengths in the visible region are mounted under the scanningstage. Thus, slices stained for histochemical or enzyme-labeledimmunohistochemical analysis as well as films such asautoradiographs, can be analyzed quantitatively.

Relationship between fluorescence intensity and quinine sulfateconcentration. Fluorescence intensity originating from 0.0005 to 50mM quinine sulfate in 0.1 N sulfuric acid was finely measured usinga MapAnalyzer or image analyzer (Hamamatsu, C1966, Japan) combinedwith an SIT camara (Hamamatsu, TH9659). Working curves from theMapAnalyzer at each photomultiplier voltage and from the imageanalyzer are indicated by solid lines (numbers indicatephotomultiplier voltage) and a dotted line, respectively. Themeasurement conditions were as follows: excitation range, 385 to425 nm; band-pass interference filter, 470 nm; and objective lens,20x/0.75 (magnification/ numerical aperture).
(See, Folia Pharmacol. Jpn. 91: 173-180, 1988)
Quantitativeimmunohistochemical
Distribution of tyrosine hydroxylase
in the coronal slice of a rat brain.


The quantitative linearity, sensitivity and resolution ofMapAnalyzer surpass those of image analyzers used with TV cameras,and the sensitivity, reproducibility and facility of this methodare greater than those of the HPLC method. Also, the measuring areaof this analyzer is far larger than that of laser confocalmicroscopes.
(See, J. Neurosci. Methods 85: 161-173, 1998)

Quantitative immunohistochemicaldistribution of tyrosine hydroxylase in the coronal slice of a ratbrain. The stained slice was measured at 20-µm intervals, and thedistribution of the intensity obtained from approximately 250,000microareas is displayed. Markedly intense tyrosine hydroxylase-likeimmunoreactivity was distributed in the dorsolateral area of theneostriatum, nucleus accumbens, olfactory tubercle and motorcortex.
Quantitative immunohistochemical distributions of glutamatedecarboxylase (left side) and substance P (right side) in the sameslices of a rat brain. Anterior (upper) and posterior (bottom)regions of the brain were analyzed. Double-stained slice wasmeasured at 20-µm intervals. Markedly intense glutamatedecarboxylase-like and substance P-like immunoreactivities weredistributed in the ventral pallidum and substantianigra.


A

B

C
Elimination of autofluorescence from the human brain slice
A: Nonspecific autofluorescence
B: Immunohistochemical fluorescence superimposed on nonspecificautofluorescence
C: Quantitative immunohistochemical distribution of cholineacetyltransferase in the
normal human brain slice, i.e., A-B
Pure immunohistochemical fluorescence intensities can beobtained automatically from human brains containing variousautofluorescences using MapAnalyzer.
Measuring points: approximately six millions at 50-µmintervals.
(See, J. Neurosci. Methods 85: 161-173, 1998)

Quantitative immunohistochemical distribution ofsubstance P in a brain slice of an ***** normal human (male, age50). Data were obtained from approximately six million regions inthe brain at 50-µm intervals. Conspicuously intense substanceP-like immunoreactivity was observed in the internal segment of theglobus pallidus. The immunoreactive intensity in the internalsegment of the globus pallidus was approximately twice as high asthat in the external segment of the globus pallidus.
(See, Neurosci. Res. 35: 339-346,1999)

Quantitative distribution of Nissl bodies in ahuman brain slice. The slice was stained with cresyl violet, andthe distribution in the globus pallidus and putamen area wasanalyzed through measurement of the transmission densities. GPe,external segment of globus pallidus; GPi, internal segment ofglobus pallidus; Pt, putamen.
(See, Neurosci. Res. 35: 339-346, 1999)

Quantitative distribution of bone calcification ofspontaneously hypertensive rats (SHR) and normotensive Wistar Kyotorats (WKY). X-ray film was reversed and the degree of blackeningwas measured. A higher level of calcification is observed in thevarious bones of SHR compared with those of the WKY.
(See, Brain Res. Bull. 30: 107-113, 1993)

-Specification -
MicroscopeEpi-fluorescence microscope
PhotometryFluorescence and Transmittance mode
Measuring spotMin. diameter: 20 µm on a slice (standard)
5 µm on a slice (option)
Light sourceHalogen lamp
DetectorPhotomultiplier tube
Scanning stageMotor-driven X-Y stage
Min. stepping movement: 1 µm, Max. stage motion: 140x140 mm
Scanning speed: 10 mm/s
Dark boxDesktop type
ComputerOS: Windows NT or Windows 2000
SoftwareNewly developed software for automatic analysis
Save mode: CSV format or BMP file
Graphics: two-dimensional and three-dimensional display

-REFERENCES -
Technical report:
Sutoo D, Akiyama K, Maeda I. The development of a highsensitivity and high linearity fluorescence microphotometry systemfor distribution analysis of neurotransmitter in the brain. FolPharmacol Jpn 91:173-180, 1988.
Sutoo D, Akiyama K, Yabe K. Quantitative mapping analyzer fordetermining the distribution of neurochemicals in the human brain.J Neurosci Methods 85:161-173, 1998.
Animal experiment:
Sutoo D, Akiyama K, Geffard M. Central dopamine-synthesisregulation by the calcium-calmodulin-dependent system. Brain ResBull 22:565-569, 1989.
Sutoo D, Akiyama K, Imamiya S. A mechanism of cadmiumpoisoning: the cross effect of calcium and cadmium in thecalmodulin-dependent system. Arch Toxicol 64:161-164, 1990.
Sutoo D, Akiyama K, Takita H. Behavioral changes incold-stressed mice related to a centralcalcium-dependent-catecholamine synthesizing system. PharmacolBiochem Behav 40:423- 428, 1991.
Sutoo D, Akiyama K, Yabe K, Kohno K. Multiple analysis oftyrosine hydroxylase and calmodulin distributions in the forebrainof the rat using a microphotometry system. Brain Res Bull26:973-982, 1991.
Akiyama K, Yabe K, Sutoo D. Quantitative immunohistochemicaldistributions of tyrosine hydroxylase and calmodulin in the brainsof spontaneously hypertensive rats, Kitasato Arch. Exp.Med. 65:199-208, 1992.
Sutoo D, Akiyama K, Takita H. The effect of convulsions on therectification of central nervous system disorders in epilepticmice. Physiol Behav 52:865-872, 1992.
Sutoo D, Akiyama K, Matsukura T, Nakamoto RK. Decrease ofcentral dopamine level in the ***** spontaneously hypertensive ratsrelated to the calcium metabolism disorder. Brain Res Bull30:107-113, 1993.

Calmodulin-dependent protein kinase II

Sutoo D. Disturbances of brain function by exogenous cadmium.In: Isaacson RL, Jensen KF, editors. The vulnerable brain andenvironmental risks, vol 3, toxins in air and water. New York:Plenum Press. pp 281-300, 1994.
Nakamura M, Fujimura Y, Yato Y, Watanabe M, Yabe Y. Changes incholine acetyltransferase activity and distribution followingincomplete cervical spinal cord injury in the rat. Neuroscience75:481-494, 1996.
Sutoo D, Akiyama K. Regulation of blood pressure withcalcium-dependent dopamine synthesizing system in the brain and itsrelated phenomena. Brain Res Rev 25: 1-26, 1997.
Nakagawasai O, Tadano T, Hozumi S, Tan-No K, Niijima F, KisaraK. Immunohistochemical estimation of brain cholineacetyltransferase and somatostatin related to the impairment ofavoidance learning induced by thiamine deficiency. Brain Res Bull52:189-196, 2000.
Hanawa M, Asano T, Akiyama K, Yabe K, Tsunoda K, Tadano T,Sutoo D. Effect of Zena F-IIIR, a liquid nutritive andtonic drug, on the neurochemical changes elicited by physicalfatigue in mice. Pharmacol Biochem Behav 66: 771-778, 2000.
Human brain analysis:
Sutoo D, Akiyama K, Yabe K, Kohno K. Quantitative analysis ofimmunohistochemical distributions of cholinergic andcatecholaminergic systems in the human brain. Neuroscience58:227-234, 1994.
Sutoo D, Yabe K, Akiyama K. Quantitative imaging of substance Pin the human brain using a brain mapping analyzer. Neurosci Res35:339 -346, 1999.
Sutoo D, Akiyama K, Yabe K. Quantitative maps of GABAergic andglutamatergic neuronal systems in the human brain. Hum Brain Map11:93-103, 2000.
Sutoo D, Akiyama K, Yabe K. Quantitative imaging of tyrosinehydroxylase and calmodulin in the human brain. J Neurosci Res63:369-376, 2001.

Tyrosine hydroxylase

熱門產(chǎn)品
產(chǎn)品名稱參考價地區(qū)公司名稱更新時間 
艾德克斯ITECH 微功耗量測以及材料研究精密源表 IT2805 200V1.5A20W 面議 深圳市 深圳市賽儀歐電子有限公司 2025-02-13 在線詢價
自動測量圖像尺寸設(shè)備 ¥560000 深圳市 深圳市中圖儀器股份有限公司 2024-08-11 在線詢價
羅卓尼克USB接口水活性快速測量探頭 面議 無錫市 無錫徽科特測控技術(shù)有限公司 2024-07-09 在線詢價
激光功率測量系統(tǒng) LPMS 面議 上海倍藍(lán)光電科技有限公司 2024-04-23 在線詢價
水分活度測量儀廠商 面議 常州市 常州金壇泰納儀器廠 2024-08-29 在線詢價
防爆油箱油位測量裝置 面議 無錫市 無錫市興洲儀器儀表有限公司 2025-02-11 在線詢價
免責(zé)申明

所展示的信息由會員自行提供,內(nèi)容的真實(shí)性、準(zhǔn)確性和合法性由發(fā)布會員負(fù)責(zé),儀表網(wǎng)對此不承擔(dān)任何責(zé)任。儀表網(wǎng)不涉及用戶間因交易而產(chǎn)生的法律關(guān)系及法律糾紛,糾紛由您自行協(xié)商解決

友情提醒 :本網(wǎng)站僅作為用戶尋找交易對象,就貨物和服務(wù)的交易進(jìn)行協(xié)商,以及獲取各類與貿(mào)易相關(guān)的服務(wù)信息的平臺。為避免產(chǎn)生購買風(fēng)險,建議您在購買相關(guān)產(chǎn)品前務(wù)必確認(rèn)供應(yīng)商資質(zhì)及產(chǎn)品質(zhì)量。過低的價格、夸張的描述、私人銀行賬戶等都有可能是虛假信息,請采購商謹(jǐn)慎對待,謹(jǐn)防欺詐,對于任何付款行為請您慎重抉擇!如您遇到欺詐等不誠信行為,請您立即與儀表網(wǎng)聯(lián)系,如查證屬實(shí),儀表網(wǎng)會對該企業(yè)商鋪?zhàn)鲎N處理,但儀表網(wǎng)不對您因此造成的損失承擔(dān)責(zé)任!

關(guān)于我們|網(wǎng)站導(dǎo)航|本站服務(wù)|會員服務(wù)|網(wǎng)站建設(shè)|特色服務(wù)|旗下網(wǎng)站|友情鏈接|在線投訴|興旺通|供應(yīng)信息

儀表網(wǎng)-儀器儀表行業(yè)“互聯(lián)網(wǎng)+”服務(wù)平臺

Copyright ybzhan.cn All Rights Reserved法律顧問:浙江天冊律師事務(wù)所 賈熙明律師ICP備案號:浙B2-20100369-24

客服熱線:0571-87756399,87759942加盟熱線:0571-87756399展會合作:0571-87759945客服郵箱:873582202@qq.com 投稿郵箱:ybzhan@qq.com

網(wǎng)站客服:服務(wù)咨詢:對外合作:儀表采購群: 儀表技術(shù)群:

版權(quán)所有©浙江興旺寶明通網(wǎng)絡(luò)有限公司


提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,勾選其他,可自行輸入要求

個人信息: