- Adjustments on oil and gas-fired heating systems
- Replaces your vibrating-bottle analyser and does much more
O2 measurement
Sensor: Electrochemical
Measurement range: 0...20.9 vol. %
Accuracy: 0.3 vol. % absolute
CO indicator (not H2 compensated)
Sensor: Semiconductor
Measurement range: 0...350 ppm
Accuracy: 50 ppm
CO Sensor (not H2 Compensated)
Sensor: Electrochemical
Measurement range: 0...3000 ppm
Accuracy: ± 5 % o.r ± 20 ppm
Inlet air temperature measurement-TA
Measurement range: 0...99.9°C with TF probe
Accuracy: 2°C: 0...50°C
opt. (for measurements accord. to pollution control regs.)
Measurement range: -20.0...99.9°C with TA probe
Accuracy: 1°C: 0...50°C
Flue-gas temperature measurement - TF
Measurement range: 0...800°C
Accuracy: 2°C: 0...125°C
3 °C: 125...250 °C
4 °C: 250...400 °C
Chimney draught, DP
Measurement range: -100...+4,000 Pa
Accuracy: 3 Pa: -20...100 Pa
3 % FSD: -1.0...4.0 hPa
CO2 determination
Display range: 0...CO2max
Resolution: 0.1 %
Flue-gas loss determination - qA
Depending on fuel, resolution 0.1%
Efficiency - h
Display range: 0...120.0 %
Resolution: 0.1 %
Dewpoint temperature measurement
Depending on fuel, resolution 0.1°C
Condensate quantity
Display in kg/m³ (gas) or kg/l (oil)
Comes with
- E 98 CO with measurement data memory and IR interface
- protective sleeve
- set of rechargeable NiCd batteries
- charger A 97 / E 98
- combustion air temperature probe 280 mm
- TD 600 fast thermal printer
- plastic case
- PTFE cone
- E 98 replacement kit