技術(shù)參數(shù):
O2: 0 to 20.9 vol.-%
CO: 0 to 4,000 vol.-ppm
高濃度CO : 0 to 32,000 vol.-ppm
NO: 0 to 2,000 vol.-ppm
NO2: 0 to 500 ppm
SO2 (選配): 0 to 4,000 ppm
煙氣溫度. (TFlue-gas): 0.0 to 800 °C
空氣溫度(TAir): -20.0 to 99.9 °C
動態(tài)壓力 (PD): ± 4,000 Pa
計算值:燃?xì)鈸p耗(qF)
效率 (h): from 0 to 120
condensation is automatically detected.
Excess air (l)
Carbon dioxide content (CO2)
Carbon monoxide content in undiluted flue-gas (COnorm):
Reference oxygen freely adjustable (standard 0 %)
Carbon monoxide content in flue-gas of solid fuel heating systems:
Reference oxygen freely adjustable (standard 13 %)
Nitric ocide in undiluted flue-gas (NOnorm):
Reference oxygen freely adjustable (standard 13 %)
Condensate amount in kg/m3 or kg/l
Flue-gas dew point
總重: approx. 1.6 kg
尺寸: 190 x 145 x 50 mm
應(yīng)用
- 可用于測量燃油、燃?xì)狻⑷济旱葻煔夥治?
- 測量方法符合國家標(biāo)準(zhǔn)
- 能同時檢測NOx濃度
- 能存儲多達(dá)580組數(shù)據(jù)
- 通過附加壓力補(bǔ)償系統(tǒng)保證壓力穩(wěn)定
- 采用輔助探桿測量K值
配置:
- AN500標(biāo)配580組數(shù)據(jù)存儲和紅外通訊接口
- 帶O2 傳感器和CO傳感器4,000 ppm
- 4節(jié)空充電小電池(NiMH) 快速充電
- 采用3.0 米長特福龍管線采樣
- 探桿手柄和主機(jī)可以距離295 mm
- 內(nèi)置溫度傳感器
- 冷凝物
- 25 塊過濾填料
- 1 個過濾器1 除水器