當(dāng)前位置:北京子午銳德科技有限公司>>職業(yè)衛(wèi)生檢測與評價儀器(物理化學(xué)因素)>>振動儀>> Svantek SVAN 974 Vibration Meter
參 考 價 | 面議 |
產(chǎn)品型號
品 牌
廠商性質(zhì)其他
所 在 地北京市
聯(lián)系方式:查看聯(lián)系方式
更新時間:2025-01-17 09:16:34瀏覽次數(shù):7次
聯(lián)系我時,請告知來自 儀表網(wǎng)Svantek SVAN 974 Vibration Meter
Svantek SV 106A Human Vibration Met
Svantek SV 100A Whole-body Vibratio
Svantek SV 103 Vibration Dosimeter
SVAN 974 Vibration Level Meter and Analyser is intended for general vibration measurements and machinery condition monitoring. It can be used by consultants, maintenance services, industry R&D departments etc.
Instrument allows parallel acceleration, velocity and displacement measurements. Three vibration profiles allow parallel measurements with independently defined filters and RMS detector time constants. Each profile provides a significant number of results (like RMS, Peak or Max).
The advanced time-history logging for each profile provides the complete information about the measured signal. Measurements data stored to microSD card can be easily downloaded to any PC using the USB interface and SvanPC++ software.
Most of required weighting filters, like VelMF, meeting ISO 10816 standard requirements, are available with this instrument. Using the computational power of its digital signal processor, the SVAN 974 instrument can perform additionally the real-time 1/1 or 1/3 octave or FFT analysis. The SVAN 974 offers also, parallel to the vibration measurement, the RPM measurement with Monarch laser tachometer.
Instrument is powered from four AA standard or rechargeable batteries. The powering of the instrument from the USB interface is also provided. The robust and very compact case together with a light-weight design complete the exceptional features of this modern instrument.
Standards | ISO 10816-1 |
Number of Profiles | 3 |
Weighting Filters | Acceleration: HP1, HP3, HP10, Wh Velocity: Vel1, Vel3, Vel10, Displacement: Dil1, Dil3, Dil10 Machine filter: VelMF (ISO 10816-1) |
Time Constants | from 100 ms to 10 s |
RMS Detector | Digital True RMS detector with Peak detection, resolution 0.1 dB |
Accelerometer | SV 80 IEPE, single axis, sensitivity 10 mV/(ms-2) ~ 100 mV/g |
Measurement Range | 0.01 ms-2 RMS ÷ 438 ms-2 Peak (with SV 80) |
Frequency Range | 1 Hz ÷ 5 kHz (with SV 80 and HP or HP1 filter) |
Internal Noise Level | Less than 10 μV RMS (IEPE input & HP1 filter) |
Dynamic Range | > 100 dB |
Vibration Analyser | |
1/1 Octave Analysis (option) | Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 1 Hz to 16 kHz (full band) with selectable weighting filter and detector |
1/3 Octave Analysis (option) | Real-time analysis meeting Class 1 requirements of IEC 61260, center frequencies from 0.8 Hz to 20 kHz (full band) with selectable weighting filter and detector |
FFT Analysis (included) | 400 or 800 or 1600 lines in selectable band from 78 Hz to 20 kHz with HP weighting filter, selectable averaging: linear or exponential, and selectable window |
RPM (option) | Rotation measurement option without Laser Tachometer (option), measurement of RPM, RPS, RMAX, RMIN |
General information | |
Input | IEPE, Charge amplifier or Direct with TNC connector |
IEPE Current | Selectable: 1.5 mA, 3.0 mA, 4.5 mA |
Frequency Range (-3 dB) | 0.7 Hz ÷ 22.6 kHz, sampling rate 48 kHz |
Memory | MicroSD card 8 GB (removable & upgradeable) |
Display | Colour 320 x 240 pixels, OLED type |
Keyboard | 9 push buttons |
Communication interfaces | USB 1.1 Client |
Power supply | Four AA alkaline or rechargeable NiMH batteries (not included) |
USB interface 500 mA HUB | |
Environmental Conditions | Temperature from -10 oC to 50 oC Humidity up to 90% RH, non-condensed |
Dimensions | 140 mm x 83 mm x 33 mm (including microphone and preamplifier) |
Weight | Approx. 0.4 kg with batteries (without accelerometer) |