Standards | IEC 61252; ANSI S1.25-1991; Class 1: IEC 61672:2002, ISO 11904-1 |
Acoustic Dosimeter Mode | Lav/Leq, SPL, Lmax, Lmin, SEL, SEL8, PSEL, LEPd, Dose (%), TWA, E, E_8h, Peak, Run Time, Upper Limit Time (ULT), L(C-A), Projected Dose (D_8h) |
SLM Mode | Leq, Spl, SEL, LEP,d, Lden, Ltm3, Ltm5, statistics - Ln (L1- L99), LMax, LMin, LPeak Simultaneous measurement in three profiles with independent set of filters and detectors |
Weighting Filters | A, C and Z |
RMS Detector | Digital true RMS detector with Peak detection, resolution 0.1 dB Time constants: Slow, Fast, Impulse |
Microphone | SV 7052E, prepolarised, 1/2" housing SV 25S, special microphone with dedicated probe for Microphone-In-Real-Ear technique (option) |
Preamplifier | SV 15 with integrated cable |
Measurement Range | 45 dBA RMS ÷ 141 dBA Peak (with SV 7052E microphone) |
Typical noise floor | less than 35 dBA |
Frequency Range | 20 Hz ÷ 20 kHz, sampling rate 48 kHz |
Dynamic Range | 100 dB |
Data Logger1 | Time-history logging of Leq/Lmax/Lmin/Peak/Lav results to internal memory with time step down to 100 millisecond to microSD card |
Audio Recorder1 | Time-domain signal events recorder (option) |
Dual-channel Mode | Dual-channel measurement mode with second microphone SV 7052E or SV 25S (option) |
1/1 Octave1 | Dual-channel 1/1 octave real-time analysis and spectra logging, 10 filters with centre frequencies from 31.5 Hz to 16 kHz, Type 1: IEC 61260 (option) |
1/3 Octave1 | Dual-channel 1/3 octave real-time analysis and spectra logging, 31 filters with centre frequencies from 20 Hz to 20 kHz, Type 1, IEC 61260 (option) |
Basic Data | |
Input | 2 x LEMO 2-pin, Direct |
Display | Colour 160 x 128 pixels OLED type |
Memory | MicroSD card 8 GB (removable & upgradeable) |
Interfaces | USB 1.1 Client Extended I/O - AC output (1 V Peak) / Digital Output (Alarm trigger) / Digital Input (Input trigger) |
Power Supply | Two AA batteries (alkaline): operation time > 16 h (3.0 V / 1.6 Ah)2 Two rechargeable batteries (not included): operation time > 20h (2.4 V / 2.6 Ah)2 USB interface: 150 mA HUB |
Environmental Conditions | Temperature: from -10 oC to 50 oC Humidity: up to 90 % RH, non-condensed |
Dimensions | 95 x 83 x 33 mm (without microphones) |
Weight | 260 grams with batteries (without microphones) |
1 function parallel to the acoustic dosimeter mode or meter mode
2 depends on instrument operation mode