當(dāng)前位置:上海頤品自動(dòng)化科技有限公司>>*防爆格蘭等>>英國(guó)Peppers防爆格蘭>> Peppers防爆格蘭頭(Peppers E1WF type glands)

Peppers防爆格蘭頭(Peppers E1WF type glands)

參  考  價(jià)面議
具體成交價(jià)以合同協(xié)議為準(zhǔn)

產(chǎn)品型號(hào)

品       牌

廠商性質(zhì)生產(chǎn)商

所  在  地上海市

聯(lián)系方式:張凱文查看聯(lián)系方式

更新時(shí)間:2022-12-07 08:37:46瀏覽次數(shù):868次

聯(lián)系我時(shí),請(qǐng)告知來(lái)自 儀表網(wǎng)
產(chǎn)地 國(guó)產(chǎn) 加工定制
EPIN英國(guó)Peppers防爆格蘭,英國(guó)Peppers防爆變徑接頭,英國(guó)Peppers防爆堵頭,英國(guó)Peppers防爆呼吸閥,英國(guó)Peppers防爆密封接頭,英國(guó)Peppers防爆螺紋適配接頭,上海頤品自動(dòng)化,技術(shù):

英國(guó)Peppers防爆密封接頭Peppers cable Gland

上海頤品自動(dòng)化,:

Including type No’s:
E1WB*F*
 2XSIE R
 3Z    
 4     
“E” type double compression glands, certified Flameproof Ex d, Increased Safety Ex e & Restricted Breathing Ex nR are suitable for use in Zone 1, Zone 2, Zone 21, Zone 22 and in Gas Groups IIA, IIB and IIC. They provide a controlled Ex d & IP seal on the cable inner sheath, an environmental seal on the outer sheath and a detachable armour specific clamping system for wire (W), braid (X) or tape (Z) armoured cables. The gland has been tested to IP66 and IP68 to 35 metres and is available with an IP O-ring seal on metric entry threads. The “IE” version allows the gland to be used with HV cables where the fault load is greater than 10.4kA and options are available for use with lead sheath, LSOH cables and extreme temperature applications.
COMPLIANCE STANDARDEN 60079-0, EN 60079-1, EN 60079-7, EN 60079-15,
EN 61241-0, EN 61241-1 IEC 60079-0,
IEC 60079-1, IEC 60079-7, IEC 61241-0,
IEC 61241-1 & IEC 60529
CERTIFICATIONATEX II 2 GD Ex d IIC / Ex e II / Ex tD A21
II 3 GD Ex nR II
IECEx Ex d IIC / Ex e II / Ex tD A21
GOST-R Ex d IICU / Ex e IIU
CSA Ex d IIC / Ex e II Class I Zone 1
Class I Division 2, Groups A, B, C & D
Class II Division 2, Groups E, F & G
Class III, Enclosure Types 3, 4 & 4X
NEPSI Ex d IIC / Ex e II
INMETRO BR - Ex d IIC / Ex e II / Ex nR II / Ex tD A21
ABS 1-1-4/7.7, 4.8-3/1.7, 4-8-3/13 and 4-8-4/27.5
MODU Rules 4-3-3/9
LLOYD’S Enclosure Systems (Part 1B)
RMRS Part XI of Rules for sea-going ships (ed.2008)
CERTIFICATE NO.ATEX SIRA 01ATEX1271X
SIRA 09ATEX1221X
IECEx SIR 07.0097X
GOST-R POCC GB.06.00853
CSA CSA 1356011
NEPSI GYJ06187X
INMETRO NCC 5878/09 X
ABS 09-LD463991-PDA
LLOYD’S 10/00056
RMRS 09.00784.011
APPLICATION
EExd Equipment
E1WF type glands will only maintain Flameproof Exd integrity when used with cable that is substantially round and compact with extruded bedding. The cable shall be deemed to be effectively filled. Ref: IEC60079-14:2002 Section 10.4.2

Gas Group

Internal Ignition Source

Enclosure Volume

Which Zone

Use E1WF Gland

IIC, IIB, IIA

NO

Any

Zone 1 or 2

YES

IIB, IIA

YES

Any

Zone 2

YES

IIB, IIA

YES

2 litres or less

Zone 1

YES


EExe Equipment

Other Equipment
Gas Group II, Zones 1 and 2Ignitable Dust, Zones 21 and 22
IP RATINGIP66 & IP68 (35 metres - 7 days), NEMA 4X
MATERIALSBrass CZ121 (E1WF)
316 Stainless Steel (E1WSF)
Inner & outer sheath seal material: Standard (E1) Neoprene, black. Option (E3) Silicone, white.
Reduced bore outer sheath seal (R) Silicone, red. (E1WFR).
VARIATIONSFor lead sheath cables the gland is fitted with a metallic continuity washer:
Brass (E2WF); 316 Stainless Steel (E2WSF).
Integral Earth version for HV applications:
Brass (E1WIEF); 316 Stainless Steel (E1WIESF)
Omission of outer seal:
Brass (D1WF); 316 Stainless Steel (D1WSF)
OPTIONSRReduced Bore Seal
CPVC Shroud (C) - PCP Shroud (P) - LSOH Shroud (3)
K or VLocknut, Earth Tag & Nylon (K) or Fibre (V) IP Washer
SIncluding Serrated Washer
1Quantity per kit
NPNickel Plated (NP) - Zinc Plated (ZP)
OPERATING TEMPERATURESNeoprene Seals -20ºC to +85ºC
Silicone Seals -60ºC to +180ºC
OPTIONAL ACCESSORIESLocknut Brass (ACBLN) / Stainless Steel (ACSLN)
Earth tag Brass (ACBET) / Stainless Steel (ACSET)
IP Washers Nylon (ACNSW) / Fibre (ACFSW)
Serrated Washer Stainless Steel (ACSSW)
Shrouds PVC (ACSPVC) / PCP (ACSPCP) / LSOH (ACSSIO)
EXAMPLE PART NUMBERSample: E1WBFCK1/NP/20/050NPT
E Type of gland featuring armour specific clamping
1 Neoprene Seals (1) - Silicone (3) - Neoprene/Lead (2) - Silicone/Lead (4)
W SWA (W) / SWB (X) or STA (Z)
B Brass (B) / Stainless Steel (S)
IE Integral Earth (see page TR-3)
F Multiple Certification
20 Gland shell size
050NPT 1/2”NPT Entry Thread
Gland Size
Entry Threads
MetricNPT/BSP
Entry Thread Length
[B]
Max Across Corners
[A]
Max Protrusion Length
Gland Seal Range
Cable Inner Sheath [C]
Cable Outer Sheath [D]
StandardReduced (R)
MinMaxMinMaxMinMax
Armour Acceptance Range
WXZ
Shroud Size
16M20 X 1.51/2" or
3/4"
1626.558.04.08.48.413.54.910.30.900.15-
0.35
L24
20sM20 X 1.51/2" or
3/4"
1626.558.08.011.712.916.09.412.50.90-
1.25
0.15-
0.35
L24
20M20 X 1.51/2" or
3/4"
1633.058.06.714.015.521.112.017.60.90-
1.25
0.15-
0.50
L30
25M25 X 1.53/4" or
1"
1641.458.013.020.020.327.416.823.91.25-
1.60
0.15-
0.50
L38
32M32 X 1.51" or
1*1/4"
1650.665.019.026.326.734.023.230.51.60-
2.00
0.15-
0.55
L46
40M40 X 1.51*1/4" or
1*1/2"
1660.572.025.032.233.040.628.636.21.60-
2.00
0.20-
0.60
L55
50sM50 x 1.51*1/2" or
2"
1671.573.031.538.239.446.734.842.42.00-
2.50
0.20-
0.60
L65
50M50 x 1.52”1671.573.036.544.145.753.241.148.52.00-
2.50
0.30-
0.80
L65
63sM63 x 1.52" or
2*1/2"
1988.076.042.550.152.159.547.554.82.500.30-
0.80
L80
63M63 x 1.52*1/2"1988.076.049.556.058.465.853.861.22.500.30-
0.80
L80
75sM75 x 1.52*1/2" or
3"
1999.082.054.562.064.872.260.268.02.500.30-
1.00
L90
75M75 x 1.53”1999.082.060.568.071.178.066.573.42.500.30-
1.00
L90
80M80 x 23" or
3*1/2"
25115.2110.062.272.077.084.071.979.43.150.45-
1.00
L104
80HM80 x 23" or
3*1/2"
25115.2110.062.272.079.690.05.085.43.150.45-
1.00
L104
85M85 x 23" or
3*1/2"
25115.2110.069.078.079.690.075.085.43.150.45-
1.00
L104
90M90 x 23*1/2" or
4"
25125.7110.074.084.088.096.082.091.43.150.45-
1.00
L114
90HM90 x 23*1/2" or
4"
25125.7110.074.084.092.0102.087.497.43.150.45-
1.00
L114
100M100 x 23*1/2" or
4"
25125.7110.082.090.092.0102.087.497.43.150.45-
1.00
L114
All Dimensions are in Millimetres
NOTES:
  • Gland size does not necessarily equate to the entry thread size. Gland size 16 is also available with an M16 x 1.5 entry thread.
  • The IP O-ring seal option is only available on metric entry threads. IP washers can be supplied for tapered entry threads.
  • Dimensions (A) & (B) may differ for glands with non metric entry threads. Please refer to our “Thread Reference Tables” for specific dimensions.
  • Where glands are fitted into non-metallic Ex e enclosures they must be included within the earth circuit of the system.
  • The user should seek expert advice if intending to combine flammable and combustible dust in one environment/installation.
  • Assembly instructions must be read prior to installation and adhered to in full.
  • Peppers supplies cable glands with parallel entry threads that conform to the flameproof threaded joint requirements of IEC/EN 60079-1 and other equivalent standards. They usually incorporate a thread run out according to the available machining techniques and will not have a full form thread for the entire length. Peppers will not be held responsible for clients’ installations where this has not been taken into account.
  • To maintain the specified IP rating, clearance holes must be in accordance with EN 50262 Table 1 and the entry device should be suitably secured.
  • For gland size 20 the silicone inner seal has a minimum diameter of 11.0mm and NOT 6.7mm
  • All gland kits supplied with silicone seals will include a PTFE IP washer in order to maintain the temperature range.

 

 

中國(guó)區(qū)分銷商:
上海頤品自動(dòng)化科技有限公司

Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

因?yàn)閷I(yè),所以放心!

會(huì)員登錄

×

請(qǐng)輸入賬號(hào)

請(qǐng)輸入密碼

=

請(qǐng)輸驗(yàn)證碼

收藏該商鋪

X
該信息已收藏!
標(biāo)簽:
保存成功

(空格分隔,最多3個(gè),單個(gè)標(biāo)簽最多10個(gè)字符)

常用:

提示

X
您的留言已提交成功!我們將在第一時(shí)間回復(fù)您~
在線留言